Method statement for construction project is a mandatory requirement even sometimes at the pre-qualification stage of a construction contractor. Any reputable building construction company will follow best construction methods in order to provide best quality of work. Many old companies are always maintaining a good documentation system hence ensuring that the method statement for …
Placing Concrete by Pumping Methods - Concrete pump pipe and Conc…
Jan 30, 2017 · The Maintenance of Concrete Pump Kefid Kefid by rose qian Concrete pump is a kind of equipment which use pipeline to convey concrete, applying to transport and supply concrete in reinforced concrete structure construction, widely …
Level Guides shall be installed for the level maintenance of concrete. Concrete Placement. Blinding concrete for the structures and trenches will be placed using a pump. Grade of concrete will be according to approved concrete design mix. Do not place the concrete more than 1.5 m height.
Specifications for Repair of Concrete." 2. Maintenance of Concrete.—Modern concrete is a very durable construction material and, if properly proportioned and placed, will give very long service under normal conditions. Many Reclamation concrete structures, however, were constructed using early concrete technology, and they have already
Pumping of concrete - SlideShare
Accumulator maintenance, charge kits and cold-weather bladder information. Insulate your Booms. It is important to insulate the booms on your concrete pump with a material that does not absorb water, like neoprene. Wrapping your boom with saran wrap before you insulate it will help maintain the integrity of the paint job on your boom as well.
Apr 15, 2015 · You have no maintenance costs. NPV is a central tool in discounted cash flow analysis and is a standard method of using the time value of money to appraise long term projects or decisions
Concrete Pump Blow ck/ Burst Lines 3 - Ensure that all safety features are fitted and used on concrete pumps as per Code of Practice – Pumping Concrete. - Position yourself where exposure to burst lines is limited - Hard hat should be worn on site when pumping concrete 1 Concrete Pump Operator Wash Down 2 Inadequate Method(s) of Plant Wash Down.
Jun 01, 2009 · The concrete foundation must be substantial enough to absorb any vibration and form a permanent rigid support for the baseplate. A frequently used rule of thumb is that the foundation should be about five times the weight of the pump/motor assembly …
Gadang Engineering (M) Sdn Bhd Public Realm Works- Method Statement for Concreting Work of Pedestrian Walkway (Broom Finish) - Rev 00 Page 9 GADANG ENGINEERING (M) SDN BHD (59575-V) TUN RAZAK EXCHANGE KUALA LUMPUR, MALAYSIA 6.3 POST CONCRETE DEFECT 6.3.1 Where the defect was detected during post concreting, the concrete repairing work shall be
Nov 04, 2020 · Hydraulic MechanicHydraulic Leakage checkedHydraulic Hose replacement
Mar 20, 2018 · 1, The maintenance method of concrete pump trucks should be checked according to the corresponding requirements and methods in the maintenance manual, and check the relevant items before and after use. 2, refer to the lubrication table, lubricate the concrete pump truck parts in …
concrete. Concrete washout. After concrete is poured at a construction site, the chutes of ready mixed concrete trucks and hoppers of concrete pump . trucks must be washed out to remove the remaining concrete before it hardens. Equipment such as wheelbarrows and hand tools also need to be washed down. At the end of each work
Jul 10, 2014 · Concrete pumping is just one way construction methods have evolved over time. By using a pump, it's easier to lay concrete than doing it by hand. If you have a large project to do, consider a concrete pump as opposed to laying concrete mix yourself. It'll make a world of difference and save you time, energy and money in the long run.
Aug 01, 2017 · What are the defects of the commercial concrete mixing plant in operation? Now the people who value this question are increasing, but also because in the days of attention to the engineering commercial concrete mixing plant people continue to increase. Now the role of concrete mixing stations in the day and the performance of the performance is more and more important.
Concrete Pump Maintenance Tips | Alliance Concrete Pumps
As with all construction equipment, the safe operation of concrete pumps depends on a number of factors including the selection and maintenance of the pump and placing boom, the planning and supervision of their use, and the competence of the operator and other personnel. If any of these are deficient, the risk of a serious
Nov 28, 2018 · The concrete mixing tank must be carefully cleaned after the end of each shift, including cleaning the internal and external parts of the mixer, the feed hopper and the discharge chute; 2. When cleaning the inside of the mixing drum, put clean water and stones in the cylinder, run for 10-15 minutes, so that it can wash the inner wall and the
Accumulator maintenance, charge kits and cold-weather bladder information. Insulate your Booms. It is important to insulate the booms on your concrete pump with a material that does not absorb water, like neoprene. Wrapping your boom with saran wrap before you insulate it will help maintain the integrity of the paint job on your boom as well.